The Life Expectancy of Your Diesel Generator

Author: Hou

Sep. 02, 2024

The Life Expectancy of Your Diesel Generator

A generator&#;s life expectancy is an essential factor to consider when investing in backup power systems. Notably, most companies in the industrial sector have already invested in diesel generators due to their countless benefits. Discover the advantages of diesel generators with our review.

dingbo contains other products and information you need, so please check it out.

What&#;s the life expectancy of your diesel generator? Learn more about the factors affecting your generator&#;s longevity. #ReactPower Click To Tweet

With a business to run, you need a generator that can run in any work environment, especially during a power outage. Such a generator will keep your business going even if there&#;s no electricity. Thankfully, diesel generators are reliable enough to do that.

Important Contributing Factors

The life expectancy of a diesel generator depends on two main factors: the size and maintenance practices of the generator. Other factors also include:

  • Brand and quality of the generator

  • Size of the generator&#;s engine

  • Environmental conditions

Let&#;s delve deeper into the two main contributing factors of a generator&#;s lifespan.

Generator Sizing

Size matters a lot when it comes to the efficiency of a diesel generator. That&#;s why you should determine the load size of the machines you plan to operate using the generator.

If you use up to 90% of a generator&#;s load capacity, there&#;s no doubt it will have a longer lifespan. It ensures that the generator will always acquire sufficient combustion pressure to hold its piston rings in place.

However, using a smaller diesel generator for a bigger load size can reduce its lifespan. In these particular situations, under-loading a generator will bring harm to its life expectancy.

Maintenance Practices

Any well-maintained generator will last longer than a poorly-maintained one, whether it&#;s a natural gas or diesel generator. To keep your generator running for many hours, it&#;s important to maintain it regularly. Don&#;t wait for a power outage to run the generator. Full maintenance of a generator involves changing the oil or air regularly, changing fuel filters, and checking if there is any change in performance.

Pro Tip: Don&#;t forget to check if your generator produces sound, smoke, vibration, or consumes more fuel than before. These signs could indicate an underlying problem that needs repair.

General Life Expectancy

Diesel generators can last for at least 15,000 hours to a maximum of 50,000 hours before needing servicing. Ultimately the life expectancy of any individual generator will depend on factors such as generator sizing and preventive maintenance practices.

The lifespan of a generator also depends on the hours it runs every year. For instance, a generator that runs for 650 hours per year can work for up to 30 years to reach a life expectancy of 20,000 hours. In the same way, the lifespan will reduce if the generator has been working for even more hours in a year.

Understanding Your Generator

A generator&#;s life expectancy relies on factors such as exercising and maintenance. To extend the life of your generator, it&#;s extremely important to prioritize the time you spend operating your generator, whether you have a power outage or not. By regularly using your generator and performing regular maintenance, you&#;ll find that you can greatly improve your generator&#;s life expectancy.

Contact us to see our wide selection of generators to keep you and your business processes running all year long.

Choosing a Generator for Your Sailboat

You can&#;t take it anymore: Your s vintage cruising sailboat didn&#;t come equipped with a factory-­installed air-conditioning system or an alternating-current generator to power it and the other AC appliances you&#;ve brought aboard. Since you&#;ve owned the boat, though, you&#;ve turned into a real believer in global warming as you try to sleep through sweaty nights on board, and finally you&#;re ready to pull out your wallet and do something about it.

So, where do you begin? The first step is to analyze how much electrical power you are going to need. Since your boat had a basic shore-power system when you bought it, you already have some idea of your small-appliance usage, things such as hair dryers, the coffee maker and maybe even a small TV. But now you need to think in terms of running this same gear while at anchor. Additionally, if the standard-equipment shore-power option for your boat at the time of purchase was a 30-amp service, as is most often the case here in the United States, you might discover that it&#;s inadequate to run that new reverse-cycle air-conditioning system you&#;re dreaming about.

This is an area where, in my experience, a lot of boat owners go into denial as they discover that more power consumption adds considerable cost. Everything you&#;ve read about marine electrical systems so far tells you that air conditioning and refrigeration use a lot of power. But how much? The good news here is that these units have become more efficient in recent years and the power needs are not as great as they were when your boat was new. As an example, a modern 18,000 Btu reverse-cycle system from Dometic Corp. will need about 15 amps of AC power to get the job done. A 10,000 Btu unit is going to draw around 8 to 10 amps, depending on your location and whether you are heating or cooling.

Advertisement

The generator installation in the engine compartment on a Maestro 40 makes good use of the boat&#;s design. The generator is easily serviced via an opening panel in the saloon.

Billy Black

Analyze Your Needs

The first step is to do an honest load analysis to see how much electrical power you will need. This is typically measured in thousands of watts, or kilowatts. The operative phrase here is: Don&#;t cheat. If you want to luxuriate in air-conditioned comfort 24-7 while cruising, it&#;ll cost you. Unlike powerboats, most cruising sailboats come equipped with liquefied petroleum gas stoves and ovens, so one of the major power consumers (an electric galley) is not a concern here.

All said, you are probably going to be looking at generators in the 4 to 12 kW size range. The typical owner of a 40-something-foot sailboat who wants to power up a reverse-cycle air-conditioning system, small galley appliances, a refrigeration system using either AC or DC power, a water heater and a battery charger is going to want an 8 kW generator. Larger boats that might end up having a clothes washer and dryer, larger reverse-cycle heating and cooling unit and water heater can easily end up in that 12 kW output range. The American Boat and Yacht Council offers a free trial membership with access to the relevant electrical power ­standard (E-11), including a complete load analysis worksheet for those who are so inclined and want a detailed account of their electrical needs. Simply go to abycinc.org to gain access via the consumer section of the site.

Engine access is excellent from the aft cabin.

Billy Black

A quick way to determine your AC power needs is to look for the mandated label on each appliance. It is required to tell you either the operating voltage and amperage draw or the operating voltage and wattage.

For more volvo generatorsinformation, please contact us. We will provide professional answers.

Related links:
What is the efficiency of asynchronous motor?
10 Questions You Should Know about Electric Motors Basics
The Benefits of Using What Is a 3 Phase Induction Motor

Advertisement

Either way, a simple equation can be applied to get the info you need: Volts multiplied by amps equals watts; or watts divided by volts gives you an amperage value. Add the number of watts each device requires and you will get an idea of what size generator you&#;ll need. Remember that it takes 1,000 watts to make 1 kilowatt. Understand that this method will actually give you a result that does not take into account the fact that you might not be running all of your appliances simultaneously. The ABYC load analysis method found in the ABYC E-11 standard offers some diversity adjustments that are more conservative and reflective of the real world.

The centerline engine compartment on a Passport 545 provides plenty of space and ready access to the generator.

Billy Black

Although modern ­generators are not as sensitive to running with a light electrical load, most installers will tell you that running them at 70 to 80 percent of their maximum capacity is better for the engine. The risk here is carbon buildup in the engine&#;s combustion chambers if run with a light load for extended periods. So, this is a case where significant overkill is not such a good thing.

The generator aboard this Lagoon 39 is installed in a roomy locker that provides ample access for maintenance, as well as the ability to reach other equipment.

Billy Black

Practical Concerns

In addition to the electrical load you need to meet with your new generator, you should also be considering its weight and physical dimensions. Will the generator fit into the space you have available? The units I compared (see &#;Generators by the Numbers,&#; page 82) ranged in weight from a low of about 270 pounds for the 5 kW Fischer Panda to a high of just under 700 pounds for an 11.5 kW Kohler. This amount of weight dictates that when installing a generator on a monohull, you&#;re going to want to keep it on the centerline of the boat. Typically, this works out well because most sailboats built from the early &#;90s on will have adequate space aft of the propulsion engine to fit in new generator. Multihulls offer more options on that front.

Advertisement

What might be a concern with the monohull is service access, not only for the generator itself, but for things like the propeller shaft stuffing box and shaft coupling. I&#;ve inspected many boats where the only way to access a leaking shaft seal was to lift the generator out of the way!

Wherever you end up installing your new generator, you need to be able to gain access to all the service points on the unit.

The physical dimensions of the generator could end up being a game changer too, so you&#;ll need to measure your boat&#;s available space carefully and compare that to the specifications for the units you are considering. You will also need to determine whether the unit will fit with a sound shield installed or not. Understand that some of the generators offer a sound shield as an option only. The presence of a sound shield, or your ability to insulate the space where you are going to have this generator mounted, could make a difference not only in size requirements but also noise issues while running.

As an example, comparing a Fischer Panda unit that comes with a standard sound shield, we get dimensions of 23 inches by 17 inches by 22 inches. A similarly rated Cummins Onan unit, which also comes with a standard sound shield, is 26 inches by 23 inches by 21 inches. A Westerbeke with a similar rating but with optional sound shield measures 36 inches by 23 inches by 25 inches. That 13-inch spread in length between the Fischer Panda and the Westerbeke could mean the difference between a doable install in the space available on your boat or not.

Advertisement

Finally, wherever you end up installing your new generator, you need to be able to gain access to all the service points on the unit. Can you get that oil filter off as installed? Can you access and change the water-pump impeller without needing an emergency ­chiropractic visit? These are questions that will need answers.

Power Perks

Several features related to newer generators are worth considering. One is whether the unit is equipped with digital controls that may also allow for self-diagnostics and integration to onboard networking that you or a former owner may have installed on the boat.

From a maintenance standpoint, you&#;ll also want to know whether the water-cooling system for the engine driving your generator is raw- or freshwater cooled. Raw water might save money initially, but will cost in the long run.

Buyers Beware

I can&#;t emphasize this enough: This sort of upgrade does not qualify as a do-it-yourself project unless you have ­considerable mechanical skills and experience, and labor will be a major addition to the overall cost of the installation.

Also, when you compare different units, study the supplied components carefully. Does the unit come with a remote display and control panel? What additional parts will you need? These will likely include an exhaust system, starter battery and cables, and raw-water supply hoses and a seacock. And don&#;t forget about wiring the generator ­into your existing, or possibly a replacement, AC ­distribution panel board. These items can add considerable cost above and beyond the generator prices shown in &#;Generators by the Numbers.&#;

If you are planning on cruising far afield with your new generator, you should also think about parts and service availability, not to mention its warranty.

Lastly, if you are planning on cruising far afield with your new generator, you should also think about parts and service availability, not to mention its warranty. As part of my ­research for this article, I looked at units from Cummins/Onan, Fischer Panda, Kohler, Northern Lights and Westerbeke. All five brands have extensive global dealer networks, so ­locating a service center that can help is just an internet search away. As for warranties, I&#;ve noted them in the &#;Generators by the Numbers&#; table. Keep in mind when reviewing this ­information that it is based on likely choices from the ­individual company&#;s offerings for a boat in the 35- to 45-foot size range. Also understand that the prices quoted are list price. Several of the dealers I spoke with suggested that discounts of $1,500 to $2,000 are quite common. That said, if you spot something you think is a deal, be certain of what you are actually getting, ­especially if it&#;s at a ­remarkably ­discounted price.

Ed Sherman is a frequent CW contributor, Boat of the Year judge and vice president of education for the American Boat and Yacht Council.

A green alternative

  • Considering the cost of installing a generator &#; estimated at $15,000 to $20,000, or possibly more depending on your boat and the power output selected &#; you might consider some alternatives.

  • How about essentially silent AC power via a direct-­current-to-alternating-current inverter and adequate storage capacity that relies on the latest high-capacity battery technology?

  • Marine electrical systems have evolved considerably over the past decade or so, and I&#;m at the point now where I question the need for an onboard AC generator for most cruisers, though some might still benefit from installing a DC generator to supplement solar-, wind- or water-driven charging solutions.

  • The current density of high-end absorbed glass mat and lithium-ion batteries has improved by 20 to 30 percent due to their inherent capacity compared to older flooded-cell batteries. They can also be discharged to deeper levels without damage and recharged much more quickly due to high absorption rates. I&#;m of the opinion that it might be time to look at alternative power if you are willing to spend the kind of money we are talking about with an AC generator upgrade for an older boat.

  • As quiet as they might claim to be, that incessant drone of an AC diesel generator, not to mention the however faint odor of diesel exhaust fumes, is going to be a reality. It&#;ll have to run all night if you want that AC keeping you cool.

  • Instead, you could run the DC generator in the morning to replenish your batteries from an overnight discharge. Or, let your solar panels and wind generator do the job. I like the concept of not having to run an engine continuously to get my AC power.

Generators By The Numbers

Brand Kilowatt Rating Sound Shield Equipped Dimensions (LWH) Freshwater Cooled Warranty Online Price Cummins/Onan 5 Yes 26&#;x20&#;x21&#; Yes 2 years unlimited; 3 years limited $9,430 7.5 Yes 26&#;x23&#;x21&#; Yes 2 years unlimited; 3 years limited $11,520 11.5 Yes 41&#;x22&#;x23&#; Yes 2 years unlimited; 3 years limited $15,052 Fischer Panda 5 Yes 21.25&#;x17.5&#;x21.9&#; Yes 5 years electrical components; 3 years engine $11,850 8 Yes 23&#;x17&#;x22&#; Yes 5 years electrical components; 3 years engine $15,200 Kohler 6 Optional 31&#;x21&#;x23&#;* Yes 5 years or 2,000 hours $8,284** 9 Optional 34&#;x21&#;x22&#;* Yes 5 years or 2,000 hours $9,563** 11 Optional 21&#;x22&#;x38&#;* Yes 5 years or 2,000 hours $10,743** Northern Lights 5 Optional 32.5&#;x21.2&#;x21.8&#;* Yes 1 year parts and labor; 2nd year parts; 3rd, 4th, 5th year select major parts $12,795*** 9 Optional 39.3&#;x25.7&#;x25.3&#;* Yes 1 year parts and labor; 2nd year parts; 3rd, 4th, 5th year select major parts $16,595*** 12 Optional 43.6&#;x27.3&#;x27.4&#;* Yes 1 year parts and labor; 2nd year parts; 3rd, 4th, 5th year select major parts $18,695*** 5.5 Optional 33.3&#;x21.1&#;x22.3&#;* Yes 5 years limited $11,800 Westerbeke 8 Optional 36.1&#;x23.2&#;x25.3&#;* Yes 5 years limited $14,194 10 Optional 36.1&#;x23.2&#;x25.3&#;* Yes 5 years limited $16,772

*All dimensions are with sound shield; **price includes sound shield; ***price does not include optional sound shield

Want more information on diesel generator installation? Feel free to contact us.

39

0

Comments

Please Join Us to post.

0/2000

All Comments ( 0 )

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name: (required)

Your Email: (required)

Subject:

Your Message: (required)