Megger DELTA4310 Insulation Power & Dissipation Factor ...

Author: Steve

May. 13, 2024

Megger DELTA4310 Insulation Power & Dissipation Factor ...

The Delta-4310 is a fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set designed for condition assessment of electrical insulation in high voltage apparatus such as transformers, bushings, circuit breakers, cables, lightning arrestors, and rotating machinery. In addition to performing insulation power factor tests, the Delta-4310 can be used to measure the excitation current of transformer windings as well as to perform automatic tip-up tests and HV turns-ratio testing (an optional TTR Capacitor is available). The test set is designed to provide a comprehensive AC insulation diagnostic test. The high power variable frequency design generates its own test signal independent of line frequency quality and the hardware design uses the latest technology available for digital filtering of the response signal. As a result, the DELTA4000 Series produces reliable results and stable readings in the shortest time with the highest accuracy, even in high interference substations.

If you are looking for more details, kindly visit our website.

Capacitance and Tan delta kit -12KV Insulation Diagnostic ...

Adiradh Energy offers  Megger make  fully automatic capacitance and tan delta kit Model Delta 4000 Series ,Resonating inductor ,High precision  C and  DF Measurement Model CDAX 605 supply all over India .Tan Delta tests are carried out for Transformer Bushing and for the Transformer Winding. Transformer Bushing Tan Delta system is similar to the CT Tan Delta Test .Tan delta  is the Ratio of the Resistive Component to the Capacitive Component of the Leakage Current. It should be minimum and ideally equal to zero.

Capacitance and Tan delta test kit  Delta4110 in India  is fully automatic designed for condition assessment of electrical insulation in high voltage apparatus such as transformers, bushings, circuit breakers, cables, lightning arresters, and rotating machinery. Measurements include voltage, output current up to 300 mA, power (loss), tan delta, inductance, power factor and capacitance. Tan delta 4110 accurate measurement results under high noise conditions as tested up to 765 kV substations. Temperature correction allows the user to estimate the actual temperature dependence of the test object by measuring capacitance and tan delta measurement over a frequency range from 1 HZ to 500 HZ and automatic voltage dependence detection.

You will get efficient and thoughtful service from Hengfeng.

Capacitance and tan Delta test system Megger DELTA4110  is designed to provide a comprehensive AC insulation diagnostic test. The high power variable frequency design generates its own test signal independent of line frequency quality and the hardware design uses the latest technology available for digital filtering of the response signal. As a result, Automatic capacitance and tan-delta test set  DELTA Series produces reliable results and stable readings in the shortest time with the highest accuracy, even in high interference substations. Adiradh Energy  offering Tan delta test kit best price  in Hyderabad,Bangalore ,Bhubaneswar,Chennai,Kochi, Pune, Visakhaparnam ,Coimbatore,Delhi, Mumbai,Noida,Kolkata,Ahmadabad,Hubli and Gurgaon. Delta4000  Series operates with PowerDB software for automatic testing and reporting or with Delta Control software for real-time manual testing

12 kV Insulation Diagnostic System  Delta40o0 series has two configurations

Want more information on tan delta test kit manufacturers? Feel free to contact us.

60

0

Comments

Please Join Us to post.

0/2000

All Comments ( 0 )

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name: (required)

Your Email: (required)

Subject:

Your Message: (required)